Check the mechanics of the switching mechanism. search, pool & drain cover safety Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. The water level is good. Water level is good, pipe connections are sealed and I checked I rings which seem fineI cant seem to figure out what is wrong. Thats all I can think of now. Profile, Create a Pool If the motor is fried, you can either replace the motor and shaft seal or spend more, and replace the entire pump (although the motor is the only thing you would really need). Could be clogged impeller? The low speed works fine. What could it be. My pump is one horse power. On/off on/off. Check fan and shroud for blockage. That is usually suitable, but 20 amp could also be used. The pump is only one year old. If so, put a damper under the pump, a piece of heavy rubber or a shim to stabilize the pump. Below is a list of common issues that can arise with your Hayward pool heater. it continues to cycle this way. This one is 5 years old. Its not raw gas, but a sour smell. Do I need to do something else to get it to prime faster? New pump probably not a shaft seal problem, just loose clamp band or volute bolts. If the wiring is Ok and the error persists, replace the sensor. What happens when you switch the output to super-chlorinate? For AquaRite, move the switch from auto to off and check all of the readings. I have a S-210 Hayward pool pump and it started spitting sand so I bought a Folding Umbrella Lateral Holder AssY when I dumped the sand out I think 2 of them were broken for a couple of months it seems sand has been dumping in the pool thats why I bought the lateral. Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. Products, Parts 2 year warranty. Does the capacitor look bulged, cracked or leaking? What do you suggest? My pressure is normal , no water being sucked in from basket and a MINOR trickle coming back out into the pool. Hi Sean, the Powerflo pump lid has a very tight seal, likely the o-ring needs to be removed, cleaned off with a rag, replaced and lubed with a Teflon lubricant like Magic lube or other Pool Lube. The water does not flow when the pump is turned on. I have a Hayward super flo matrix pump. How Much Salt Belongs In Your Pool Also check other possible pressure side problems, like a closed or broken exit valve on the filter, or other restrictions further down the line, up to the pool return fittings. You are also using the diffuser? We would like to show you a description here but the site wont allow us. That is the black cylinder in the rear of the motor, located at 9 oclock. Its a Hayward self-priming Super Pump. The switch or voltage selector, I believe it should be only over one tab, but check the owners manual, or the wiring diagram on the motor. I have an older Haywood super pump 3/4 hp, i replaced it with a new 3/4 hp motor. Is it rigid PVC or flexible pipe? 99% of the time its no problem 1% of the time something could burst, usually a plumbing fitting, a bad glue joint or clamped fitting. If you have trouble getting past this, an electrician may be a good call to make. Hola Ral, Podra ser una de 4 cosas: encendedor, sensor de fuego, baja presin de gas o el tablero de control. In some instances, it could just be a bad breaker. This is a black cylinder located in the back of the motor, at 9 oclock, which acts as a battery to give the motor extra juice to start. We have a sand filter and no pressure gage. If the breaker is GFI, those are very sensitive, could be a bad breaker too. Hopefully the GFI then holds. A wire connected to the terminal board may be loose or burnt. I will be purchasing a replacement pump and have it installed, but I wonder if Id need to just have the breakers tightened in the panel box? Scrape out the old gasket with a sharp screwdriver and glue a new one in place with dabs of superglue gasket flat side down, ridged side up. Check the incoming motor voltage to be sure it is correct, too low or too high can cause problems. how to watch past broadcasts on twitch. http://www.inyopools.com/blogSHOP at our online store! ), 2) the pump lid o-ring (is it lubed? "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Hi Heidi, it sounds like maybe the plumbing could be reversed? This is a brand new pump out of the box that was installed and the inlet is drawing water in and filling basket and the outlet is discharging water but it just trips the breaker everytime. Put things back together and still have error. I needed to rotate the housing pump but for some reason the screws dont seem to b lined up. Improving air flow can also help, by trimming bushes or killing weeds, anything to let more breezes into the motor area. Thanks for the help troubleshooting it. 6. inspect conduit and wires going from timer to pump, look for water in the conduit, or broken conduit, or rodent damage to wires. But not a dirty filter? hopefully. The pump keeps kicking off every 24 hours and I turn it back on by hitting filter. Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. Could be a short in the wiring that could be tested with an Ohm meter, for resistance. Lube Gasket (after cleaning, with a rag lube with Teflon or Silicone based pool lube) and 3. A TEST button that is popped? Now if its not an air leak, surging can also be caused by a clog in the pipe, usually a solid object like a golf ball, getting sucked back and forth in the pipe. Have no power at all going to my control panel. Our Hayward pump is leaking and we just added our opening chemicals. Air could also be entering the pump from the threaded pipe or union that is attached to the inlet port, which may also spray or drip when the pump shuts off. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Hi David, impellers that have signs of wear are usually operating without a problem. Hi Tom, there is an o-ring that seals up the tank flange to the valve flange, its usually on the valve, when you remove the valve, might need replacement and/or a good cleaning and lubing. This year, I noticed at times that the flow rate on low speed is less than it was last year. Hi Andy, breakers are not usually screwed down, they snap in place, you can try pushing firmly on the front of the breaker with fingers, to be sure it is seated properly. Breakers and outlets do go bad after many years, usually last over 20 yrs, but can fail sooner. Typically, the LED light should shut off after 60 seconds. Do I need to clean filter? This could drain the pool down to the skimmer, or possibly much lower in some cases, so keep a close eye on any leak and look for signs of worsening. But, you know whats not great? Also check other wires in the back of the motor. You could provide a kind of tabletop shade to the motor, but dont enclose it and restrict air flow. Hi Clara click doesnt sound like a motor runnning, perhaps you are hearing a relay click, but if the motor itself is not turning over there could be a multitude of reasons why, but in most of these cases, the problem lies where the power dies. Some times it has overheated, it did re start, but I want to make sure that the motor is supposed to run continuously. Does anyone know what Im talking about and/or know how to repair? Or very high mineral content (very hard water), or oily substances. Step 3: Double check the wires on the flow switch for damage. For the green water, drop the pH to 7.2 and add enough shock until the water turns blue-ish, and run the filter 24/7. Does the LED light turn off after 60 seconds? It could also be an obstruction in the exhaust, like a birds nest in there, blocking the air flow from the fan. Then the others are 2-high speed and 1-low speed wire see the diagram on this page: http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html. After the click, immediately push the diagnostic button 5 times to begin the recalibration stage. It seems to only operate in the highest speed. Remove the back of the motor and look for anything loose wires, switches, tabs. I cant imagine paying someone to take 2 bolts off. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. So I installed a brand new Hayward W3SP2610X15 Super Pump Pool Pump, 1.5 HP last season Summer 2019 and used the electric cord from the old one which was showing its age. Put your power leads on both sides of the transformer, should be 115V IN, and 28V OUT, (or close to those numbers). Check the serial number on the pumps sticker. "@context": "https://schema.org/",
Hi Sal, for the pump lid, it may help to close the incoming and outgoing valves, and open the filter air bleeder, to release the suction. Overheating can be a short across the windings, or it can be other major faults within the motor. I have a perflex ec50 that is about four years old. If you have an electric motor repair shop in town, they may have it in stock, or order it online. Is there any other switch? What can I do? Unusual, but it could be the only problem, I would replace the capacitor with the same size (match the MFD number), and check that the shaft rotates freely when mounted to the pump. Hose them off well, and then soak them in a DE filter cleaner, in a 5 gallon bucket. Hi Christy, there may be a GFCI test button that popped, on an outlet below the breaker box, or on a light pole? },
. Especially a drip from the clamp band or the threaded fitting on the outlet port of the pump, or a dripping shaft seal, or leaking housing. How To Recalibrate The Average Salt Level. You must log in or register to reply here. This he says is because the drive is intermittently failing and the pump will need to be replaced. Pushing down on the handle briefly (pump off) can often dislodge the debris, and no gasket replacement is necessary if you are lucky. Then, I tried plugged the pump into another power outlet and it still does not work. I checked the possible issues that you mentioned hereno drain plugs on the systemdraining pool is done through the filter via a valve that is after the filter (Perflex). Inspect the area where the wires connect to the motor, aside from that Im stumped havent had the chance yet to work on too many VS motors. Typically, any dilemmas with your Hayward pool pump are likely related to either electrical or plumbing situations. Old broken wires inside of the conduit could be the problem. The new pump was very quiet yesterday when I installed it, but this morning, I notice there is a slight medium pitch hum in the system. It worked great for the season. . If the pump runs air tight, but slowly drains out over an hour or so, that is usually a pressure side (after the impeller) air leak. Thank you so much for taking time to answer all our concerns. Hi Deb, probably a bad outlet or a bad cord, or a loose connection on one or both of those. After reinstalling, give it the full charge of DE powder, plus a little extra. All the hoses have new Teflon tape and they are secured. If it clogs up again, you will need to break it down and manual clean, then soak in DE Filter Cleaner not so hard and the best cleaning, just a lot of little nuts and washers to remove and replace. You can remove the wires and call your local Electric Motor Repair Shop, and see if they have this capacitor in stock, just read them the MFD number range printed on the side of the black cylinder. I just replaced a Hayward 2 hp SP2615X20 that started making a loud noise while still pumping, so I figured the bearings or something were gone, with a Hayward SP3015X20AZ 2 hp. Hi Davy~ Replace the plumbing with a new fitting, using a silicone thread sealant and 3-4 wraps of teflon tape clockwise. I really dont know how long the motor was running like this when I discover the problem when I discover the problem the motor had already shut off. there is an air leak, on the pump lid, or around the pipe that comes into the pump, or the pump drain plug. If the shaft spins freely, no rust problem. La mayora de las veces la vlvula de gas est cerrada, el tanque de propano est bajo, el encendedor est roto o el sensor de fuego no est colocado correctamente. No loose wires or insect infestation. Low speed should be enough flow to activate the flow switch. It could be air in the pump, or it could be that the pump is too big (powerful) for the number of pipes. 5. inspect all wires inside the back of motor, looking for one that is disconnected, cut, crimped, or two metal terminals touching each other. I replaced the motor a couple of years ago. But, that may not be it, if you say the shaft is getting stuck each time? I assume from your post that there are 2 possibilities 1) bad capacitor (I assume I can spot it visually) or 2) frozen shaft or propeller (how do I spot it and fix it? There can be multiple reasons for a pool pump not priming correctly. HI Alberto, if a motor is overheating, it normally takes about 15-20 minutes, and then the thermal overload switch, located in the rear of the motor, will trip, shutting off the pump for about 15-20 minutes, until it is cool enough to start again, on its own. Timer 1 comes on at 10:30 at 1450rpms and runs to 3:30. Could be the pump lid, drain plug, or the pipe that threads into the pump. The air may be there on high speed too, its just not noticeable. Thank you If not, the parts internally, some parts, need replacement. "@type": "BlogPosting",
However this is not correct operation. I was hoping that you can give me some advice. Thoughts? It sounds more like a filter problem, one that might be fixed by using a good pool filter cleaner, or you may need new filter media. If the motor makes no noise at all, not even a peep, then its usually a power issue. Jul 8, 2018 #1 I have a blue essense 20,000 salt system and can find very little online. I open the plastic door, fill with water and sometimes need to do this several times in order for it to keep going. I will be replacing it tomorrow along with the electric socket. Check all wires and switches and connections in the back of the motor, look for anything loose or ant infested or broken connections. You dont have a saltwater pool do you? Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. Everything is Primed and ready to go, soon as I put the vacuumin on the skimmer, the pressure stays for about 30 secs then the pressure and water level drop to next to nothing. Hi Sara, could the sound be the gas whistling thru the burner orifices? And if you have Hayward heater error codes on display, that makes finding the problem almost easy! use a wrench on the rear of the shaft (or large flathead),to work the shaft back and forth until it spins freely. Theres no sound, when we hit the power switch no power. iv also replaced o rings and filter basket gasket. Hi Davy, A large pair of channel type pliers can be placed on the impeller, over a cloth, and given some persuasion. Hi, Everything just went downhill. Its concerning to suddenly hear strange sounds coming from your Hayward pool pump. I used the override switch and it fired up and left it on for several hours then turned it over to auto and it worked again but has since stopped. Any help,appreciated. What do I need to replace the seal plate, the diffuser, the pump housing? Inspect the centrifugal switch on the end of the shaft and the stationary switch mounted at 6 oclock and contacting the central centrifugal switch make sure all are intact and tightly secured, and not bent, broken or affected by mud or insects. Thinking of switching to PentAir, I hear they are better built. I have a Hayward C900 Filter. When we turned it on heard a pop and blew fuse. Hi Pat, good question you can continue to use the IG pump, no problem. Even with the cells reverse polarity feature, the scale will still form on the plates. Is it problem of filter ? Hi Jeff, probably that sound is worn bearings (pumps dont have brushes). The pump is working fine, however only the low speed is working. Well the electrician said it was a bad motor and to contact hayward to replace. thoughts? Pull out the pump basket and reach back thru the volute to feel the impeller with your fingertips (pump off, lol), if you feel any debris, reach in with needlenose pliers, or pull apart the pump and ream the impeller vanes with a length of wire or a small screwdriver. You only need to touch both terminals briefly with the tip of an insulated screwdriver, to discharge the capacitor. It would be best to not abandon the pipe if possible, best for water quality, clarity and turnover rates but sometimes thats not feasible so either way will work! It DOES turn on. Any ideas why? Do you think my pump is gone or is it just needing more water to achieve prime again? Sometimes you can pull out the clog with needle nose pliers. I filled the pool to the level line, but the air bubbles stayed. Automation, Learn About First, in regard to my Hayward pump basket lid, it is hard to turn counter clockwise, when i need to remove it but it does turn. $579 + Free Shipping in USA. If it is not, re-align your flow switch. Hi, I have a hayword C48L2N134B3 1.5 HP pool pump. Pumps can also leak water from the shaft seal, which can appear to be a housing/seal plate leak, but will leak only directly from the bottom. We replaced the handle assembly and valve per Hayward tech support that hasnt fixed the problem. Secondly, check that there are no air leaks in FRONT of the pump, typically around the pump lid, or on the pipe coming into the pump. Look for any small drips or oozing around the filter, or you may be able to hear a small hiss, when the pump shuts off. 1. One of the tads were not in the slot. I have a Hayward super pump 1HP. Recently replaced mortor and pump. When it stops again, you may want to pull off the filter valve from the filter, and inspect the top few inches of sand, maybe replacing it with new. If needed, you could replace just the motor, and the shaft seal, and save a few hundred bucks. Start up again with a fresh (Full) charge of DE powder. Verify if your flow switch was installed correctly. Pump is primed and water is coming out of the returns. I checked the pump and is is very hot. Hi Paul, Ants can be a problem, when they get around motors or circuit boards, but it sounds like a pump motor problem, and could simply be a weak capacitor, in the rear of the motor (black cylinder). After resetting the switch 3 times yesterday,the pump is finally staying on. ), it could be a bad breaker, they can fail or become too sensitive with age. the , . Pump lid not on tight, gasket not lubed, or not positioned properly (superpump) Hi thanks for speedy reply the breaker is 20 amp with a GFCI. You need to be really sure about the actual salinity reading. Hi Steve, this can be from reduced flow, like a VS pump running on low speed, and some water vaporizing into steam. It had a non Hayward motor installed before. Usually get 3-4x that long. If valve is open when it should be closed the heater will shut down and go into lockout. Just replaced the sand and cleaned the fingers, replaced the o rings and have a psi of 15 and great suction. Hola tengo una caldera Hayward H400 PED2 durante el intento de encendido no enciende m caldera despus de 5 intentos me pone lF en la pantalla. Seems like filter is dirty , so I bumped it several times (once with motor on to really force water through) that usually does it. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. If the set screws loosen, the impeller can slide forward and contact the pump housing, and grind both the bronze housing and bronze impeller down rapidly. Davy, Whenever Ive seen that its from too much voltage, like connecting 220V to a motor wired for 110V. Some motors, esp. If the amps on either reading show zero (0), then you should replace your PC Board. I reached into the impeller and grabbed it but it seemed still tight. Replace with exact MFD number, printed on side. This blog is an in-depth look at the Aqua Rite and Aqua Rite XL diagnostics manual created by Hayward. I just purchased a brand new Hayward Super Pump 1.5HP for my pool that is being renovated. Inspect the following areas: If you see air bubbles coming from the return fittings on the pump, there may be an air leak on the suction side. If it is reversible is lists voltage on the label as 115V/230V, but if 230V only, it just says 230V. Tried to vacuum. After we run the pump for a few minutes and then take the pump apart there is water in the impeller- but the water is where the seat housing is. For this issue you are having, I would bump and drain the filter of the DE powder and add a recharge of DE powder thru the skimmer, and give it another go. Hi, We had a pool installed last fall and we are still figuring things out. Hi, might have been a small clog in the pipe. "primaryImageOfPage": {
The high temp limit that is the pump motor as a thermal overload switch (located at 12 oclock in rear of motor), that will shut the motor down and prevent restart until the overload senses lower temps and resets itself, at which point the pump should turn on again, by itself. Where can I get a new yellow wire to connect the motor to the switch and see if this solves my issue? Hi Anessa, Hayward VS pumps are known to have Drive Errors, whereas Pentair, I dont hear so many problems about the Intelliflo. Please help. You might be surprised by how many people neglect to check this area. Be sure all lines are open, and again check for air leaks. Heres a link to the Hayward Heater Owners Manual, which may be helpful. Could be too much or too little sand, the filter should be about 2/3 full of sand. You have both filter pump and polaris pump on one timer? Does the panel just need to dry or did I cause possible damage? Hi Originally it appears that the arrows are just off a little, but not the case. Move switch to center position and adjust dial to a percentage that you think it needs. I also have voltage (115 volts)on both sides of the fuse holder with no fuse installed. Any ideas on troubleshooting this issue? I had my Hayward pool/spa installed about 4 years ago. Hi there. Any ideas as to how to fix this? If the control is not in lockout and senses that the igniter circuit is open when the blower is running the control will turn off the blower and go into lockout. Problem is now the pool will not clean up (algae) and the pump is slow to prime. that sounds like loose wires, or broken wires. Hi Larry, When DE is coming back into the pool, its usually: I even tried another new housing gasket and it still leaks. larger hp motors, are not reversible. In most cases, if there is a blockage, your pumps pressure increases. "width": "611",
switch and to the capacitor, to be sure nothing is loose or no crimped wires. We knows its not electrical. thanks. Hi Todd, that would be rare but not impossible sometimes bearings are not set perfectly, or manufactured perfectly, or the tolerances of the bearing housing could be off by a hair, from something being loose, or mis-shaped or if the motor were dropped from a height. What am I doing wrong?? My pump motor does not start until I spin the shaft then it runs for about 15 min and shuts off and I can hear the motor humming and it feels very hot to the touch. Thanks Davy for your quick reply. Is this normal operation or should I look into replacing the strainer cover o ring? Have a Hayward pump for above ground pool.when I start the pump it works properly and then itll stop pumping water. This quick spray of water when you shut the pump off, as you have experienced, are a useful tool in locating an air leak on a pump. the problem lies, where the power dies. I would turn it off and it would hum and eventually start. Also check that the water level is high enough, and that a skimmer weir is not stuck in the up position, blocking water flow. The motor eventually started. Products, View If you attached the cord, make sure that the wires are correctly attached to the terminal board, and the ground wire secure. Not the 12VAC that it says should be there. Any suggestions? If symptoms continues with the filter on recirculate, you would have different problems, like restriction or obstruction in the pipes. At first, the pump would only hum and not work. I have replaced my existing super pump with new one. You are using an out of date browser. Hi We just bought a new Hayward Powerflo Matrix pump and filter. The pump has power, turns on, and seals are tight, however it will not cycle the water. 1. ), or 4) loose suction side valves, I have a hayward 1081 century with 3/4 hp motor with top mounted capacitor. Guess it is time for a new drive. Hi Jeanna, most of those slide from 230 to 115, but some do have to be unplugged and replugged. Third possibility is the pipe size is too small, and your 90 gpm pump may be starved for water. I have a Heyward VS 500 that suddenly started making a sound like a poker card stuck in your spokes of your bike at all speeds. Hi Did you figure out your problem? Shut it off & starting looking for help online. Most Common areas include the pump lid (must be very tight, with lubed lid o-ring), and the threaded pipe that comes into the FRONT of the pump (must be very tight and sealed if loose, use Pool Putty to fix, or replace the fitting) the effluent or exit pipe fitting leaking will not draw air, that is on the pressure side not the suction side.